Sale!

VICTRON ENERGY – Lynx Smart BMS 500 (M8)

R 11,934,65

Lynx Smart BMS 500

The Lynx Smart BMS is a dedicated Battery Management System for Victron Lithium Smart Batteries. There are multiple BMS-es available for our Smart Lithium series of batteries, and the Lynx Smart is the most feature rich and complete option.

Specifications:

  • Brand: Victron Energy
  • Manufacturer Part Number: LYN034160200
  • Battery voltage range: 9 – 58Vdc
  • Maximum input voltage: 75Vdc
  • Supported system voltages: 12, 24 or 48V
  • Reverse polarity protection: No
  • Main safety contactor continuous current rating: 500Adc continuous
  • Main safety contactor peak current rating: 600A for 5 minutes
  • Power consumption OFF mode: 0.3mA for all system voltages
  • Power consumption in Standby mode: Approximately 0.6W (50mA at 12V)
  • Power consumption in ON mode: Approx. 2.6W (217mA at 12V) depending on the state of the relays
  • Minimum load resistance for pre-charging: 10Ω and above for 12V systems 20Ω and above for 24V and 48V systems
  • AUX output maximum current rating: 1.1A continuous, protected by resettable fuse
  • Allow-to-charge port Maximum current rating: 0.5A at 60Vdc, protected by resettable fuse
  • Allow-to-discharge port Maximum current rating: 0.5A at 60Vdc, protected by resettable fuse
  • Alarm relay (SPDT) Maximum current rating: 2A at 60Vdc
  • Busbar: M8 (Torque: 10 Nm)
  • VE.Can: RJ45
  • I/O: Removable multi-connector with screw terminals
  • Battery BTV cables: Male and female circular 3-pole connector with M8 screw ring Up to 20 batteries can be connected in one system
  • Lynx Distributor fuse monitoring (up to 4 modules): RJ10 (cable ships with each Lynx Distributor)
  • Enclosure material: ABS
  • Busbar material: Tinned copper
  • Busbar dimensions (h x w): 8 x 30 mm
  • Operating temperature range: -40°C to 60°
  • Storage temperature range: -40°C to 60°
  • Humidity: Max. 95% (non-condensing)
  • Protection class: IP22
  • Dimensions: H184 x W170 x D80
  • Weight: 2.2kg
  • Warranty: 5 Years

Subtotal:

Add-ons total:

Total:

Lynx Smart BMS

The Lynx Smart BMS is a dedicated Battery Management System (BMS) for the Victron Smart lithium batteries. These batteries are Lithium Iron Phosphate (LiFePO4) batteries and are available in 12.8V or 25.6V in various capacities. They can be connected in series, parallel and series/parallel so that a battery bank can be built for system voltages of 12V, 24V or 48V. The maximum number of batteries in one system is 20, which results in a maximum energy storage of 84kWh in a 12V and up to 102kWh in a 24V1) and 48V1) system.

Out of the various available BMSes, the Lynx Smart BMS is the most feature rich and complete option and integrates seamlessly into the Lynx Distributor system.

Built-in 500A contactor

The contactor acts as a secondary safety system to protect the battery in case the primary controls (ATC, ATD and/or DVCC) fail to disable loads and/or chargers when required and is also suitable as a remote controllable main system switch.

Pre-charge circuit

In addition to the contactor, a built-in pre-charge circuit prevents high inrush currents when connecting a capacitive load such as a MultiPlus/Quattro or other inverter, eliminating the need for external pre-charging.

Monitoring and control

Monitor and control the BMS via Bluetooth using the VictronConnect App or a GX device such as a Cerbo GX and the VRM Portal. A built-in battery monitor that operates in a similar fashion as the other Victron Energy battery monitors, provides data such as state of charge, voltage, current, historical data, status info and more in real time, and with Instant Readout even without the need to connect to the BMS, allowing diagnostic at a glance.

DVCC closed loop control as well as ATC/ATD contacts

Compatible Victron inverter/chargers and solar chargers are automatically controlled via a connected GX device and DVCC. The ATC/ATD contacts can be used to control other chargers and loads that have a remote on/off port.

Programmable relay

The relay can be used either as an alarm relay (combined with the pre-alarm) or to control an alternator via its external regulator (ignition cable). In Alternator ATC mode, the relay will only activate when the contactor is closed. Alternator ATC contact of the alternator opens first and then with a delay of 2 seconds the contactor. These 2 seconds ensure that the alternator is switched off before the battery is disconnected from the system.

AUX terminal

The advantage of the onboard auxiliary power supply (1.1A @ system voltage) is to provide power to specific loads (i.e. a GX device) after the BMS has shut down the loads in the event of a low cell voltage event. If no charge voltage is detected within 5 minutes, the BMS including the AUX connection switches off.

VE.Can and NMEA 2000 data communication

VE.Can allows for easy connection (standard RJ45 network cable) and communication with a GX device. Since the CANbus protocol is based on NMEA 2000 (and J1939), it is easy to integrate into a marine network and feed your marine MFD with data (requires a VE.Can to NMEA 2000 micro-C male cable).

Weight 2,2 kg