INPUT DATA
Number of MPP Trackers
- 2.0
Max. Input Current (Idc Max)
- 16/16A
Max. Short Circuit Current, Module Array
- 24/24A
DC Input Voltage Range (Udc min – Udc max)
- 150-1000V
Feed-in Start Voltage (Udc start)
- 200.0V
Nominal Input Voltage (Udc,r)
- 595.0V
MPP Voltage Range ( Umpp min – Umpp max)
- 195-800V
Usable MPP Voltage Range
- 150-800V
Number of DC Connections
- 2+2
Max. PV Generator Power (Pdc max)
- 12.0 kWpeak
OUTPUT DATA
AC Nominal Output (Pac,r)
- 6000.0 W
Max. Output Power (Pac max)
- 6000.0 VA
AC Output Current (Iac nom)
- 8.7 A
Grid Connection (Uac, r)
- 3~NPE 400/230, 3~NPE380/220V
AC Voltage Range (U min – U max)
- 150-280V
Frequency (fr)
- 50/60Hz
Frequency Range (fmin – fmax)
- 45-65Hz
Total Harmonic Distortion
- <3%
Power Factor (cos pac, r)
- 0.85 -1 ind./cap.
GENERAL DATA
Height
- 645.0 mm
Width
- 431.0 mm
Depth
- 204.0 mm
Weight
- 19.9 kg
Degree of Protection
- IP65
Protection Class
- 1.0
Overvoltage Category (DC/AC) 1)
- 2/3
Night-time Consumption
- <1W
Inverter Design
- Transformerless
Cooling
- Regulated Air Cooling
Installation
- Indoors Ad Outdoors
Ambient Temperature Range
- -25 Deg. Celsius – +60 Deg. Celsius
Permitted Humidity
- 0-100%
Max. Altitude 2)
- 2. 000 M / 3. 400 M
DC Connection Technology
- 4 x DC+ and 4 x DC- Screw Terminals 2.5 -16mm2 (16mm2 without ferrules)
AC Connection Technology
- 5-pin AC Screw Terminals 2.5 -16mm2 (16mm2 without ferrules)
PROTECTION DEVICES
DC Installation Measurement
- Yes
Overload Behaviour
- Operating Point Shift, Power Limitation
DC Disconnector
- Yes
Reverse Polarity Protection
- Yes
EFFICIENCY
Max Efficiency (PV – grid)
- 98.0%
European Efficiency (nEU)
- 97.5%
N at 5% Pac, r 3)
- 87.8 / 92.6 / 87.8%
N at 10% Pac, r 3)
- 91.3 / 95.6 / 93.0%
N at 20% Pac, r 3)
- 94.1 / 97.1 / 95.9%
N at 25% Pac, r 3)
- 94.7 / 97.5 / 96.5%
N at 30% Pac, r 3)
- 95.1 / 97.7 / 96.8%
N at 50% Pac, r 3)
- 95.7 / 98.0 / 97.5%
N at 75% Pac, r 3)
- 95.7 / 98.0 / 97.6%
N at 100% Pac, r 3)
- 95.7 / 97.9 / 97.6%
MPP Addition Efficiency
- >99.9%
INTERFACES
WLAN/Ethernet LAN
- Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 Inputs and 4 Digital Inputs/Outputs
- Interface to Ripple Control Receiver
USB (Type A Socket )4)
- Data Logging, Inverter Update via USB Flash Drive
2 x RS422 (RJ45 Socket)4)
- Fronius Solar Net
Signalling Output 4)
- Energy Management (Floating Relay Output)
Datalogger and Web Server
- Integrated
External Input 4)
- SO Meter Connection / Evaluation of Overvoltage Protection
RS485
- Modbus RTU SunSpec or Meter Connection