GENERAL SPECIFICATIONS
-
Power Supply (Φ / V / Hz) – Indoor
1/220~240/50
-
Capacity (Min / Nom / Max) – Cooling
4.0 / 10.0 / 11.0 (kW)
-
Power Input (Set) – Cooling
3.1 kW
-
EER
3.3 Btu/h/W
-
Power Supply (Φ / V / Hz) – Outdoor
3/380~415/50
-
Capacity (Min / Nom / Max) – Heating
4.5 / 11.2 / 12.3 (kW)
-
Power Input (Set) – Heating
3.2 kW
-
COP
3.5 W/W
INDOOR UNIT
-
Running Current – Cooling
4.4 A
-
Air Flow Rate (H/M/L)
32.0 / 29.0 / 26.0 CMM
-
Dehumidification Rate
4.0 ℓ/h
-
Body Dimensions (W x H x D)
1,182 x 298 x 450 mm
-
Running Current – Heating
4.6 A
-
External Static Pressure
4 ~ 10 mmAq
-
Drain (O.D. / I.D.)
Ø 32 / 25 mm
-
Net Weight
38 kg
OUTDOOR UNIT
-
Compressor Type
Twin Rotary
-
Sound Level (H) – Heating
54 dB(A)
-
Net Weight
85 kg
-
Piping Connections (gas)
Ø 15.88 mm
-
Max. Elevation Difference (Indoor-Outdoor)
30 m
-
Sound Level (H) – Cooling
53 dB(A)
-
Dimensions (W x H x D)
870 x 800 x 320 mm
-
Piping Connections (Liquid)
Ø 9.52 mm
-
Max. Piping Length (Main Piping)
50 m